Air-Cooled Chiller Units
Air-cooled chiller units reject condenser heat directly to the atmosphere.
Thule Series Chiller
An industrial air-cooled chiller range from 2 to 2,000 kW with scroll or screw compressors and inverter fans as standard.
- Capacity
- 2–2,000 kW
- Compressor
- Scroll / screw
Chemic Series Chiller
A 40–160 kW air-cooled chiller range using natural R290 refrigerant, microchannel condensers and EC fans.
- Capacity
- 40–160 kW
- Refrigerant
- R290 (propane)
Zero Series Chiller
A high-efficiency 10–1,800 kW air-cooled chiller range with R1234ze, GWP 1.37 and inverter fan technology.
- Capacity
- 10–1,800 kW
- Refrigerant
- R1234ze
Industrial air-cooled chillers, 2–2,000 kW
An air-cooled chiller rejects condenser heat directly to the outdoor air through fans, so it needs no cooling tower, condenser water circuit or plant room. That makes it the most straightforward way to add process cooling to an existing facility, and the usual choice where water is scarce or a cooling-water circuit would be costly to build.
Carnot's air-cooled range spans 2 to 2,000 kW in three series and includes configurations for laser cooling and low-temperature processes.
Thule vs Chemic vs ZERO — which series fits?
| Series | Capacity | Refrigerant | Technology | Typical use |
|---|---|---|---|---|
| Thule | 2–2,000 kW | R407C | Scroll or screw compressors, inverter fans as standard | General process cooling and air conditioning, high ambient temperatures |
| Chemic | 40–160 kW | R290 (propane) | Microchannel condenser, EC fans, microprocessor control | Mid-size loads where a natural refrigerant is preferred |
| ZERO air-cooled | 10–1,800 kW | R1234ze (GWP 1.37) | Microchannel exchanger, EC fans | Projects with low-GWP refrigerant targets |
If the refrigerant strategy is open, Thule offers the widest capacity range; Chemic and ZERO are the options when the F-gas phase-down and low-GWP refrigerants drive the decision.
Outdoor installation and inverter fan control
Air-cooled units are installed outdoors, at ground level or on the roof. Condenser performance depends directly on the ambient temperature, so units are selected for the site's summer design conditions; Thule is designed for stable operation at high ambient temperatures.
Inverter (EC) fans adjust airflow to the actual load and condensing pressure instead of running at full speed. At part load and in cooler weather this reduces fan energy and operating noise.
For outdoor operation in winter, freeze protection for the water circuit — glycol or a heated circuit — is defined at the design stage.
Air-cooled chillers with free cooling
Where process water is needed all year, cold outdoor air can carry part of the load. In winter and the transitional seasons a free-cooling coil pre-cools the return water before it reaches the chiller, and when it is cold enough the compressors can stop entirely. Carnot's free cooling solutions are covered under Dry Cooler and Free Cooling Units.
Frequently asked questions
Let's engineer solutions tailored to your needs
By analyzing your process and operational data against engineering criteria, we determine capacity, system configuration, and implementation details. Let's turn your technical requirements into the right equipment selection and an actionable system design.