TUNDRA Water-Cooled Chiller

TUNDRA provides high-efficiency water-cooled chiller solutions from 30 to 4,000 kW with scroll or screw compressor options.

Water-Cooled Chiller Units

Inside the series

The TUNDRA Series is a water-cooled chiller family developed for industrial processes and central air-conditioning applications requiring high capacity, stable water temperature and uninterrupted operation. Produced in a 30–4,000 kW range, it can be configured with scroll or screw compressors according to the project capacity and operating conditions.

Water-cooled condenser technology makes the system less susceptible to changes in ambient temperature and allows it to operate under controlled condensing conditions. With low condensing pressure and high-efficiency heat exchangers, the TUNDRA Series delivers high COP values and low energy consumption, particularly in continuously operating facilities with high cooling-capacity requirements.

Each TUNDRA chiller is selected specifically for the project by considering required cooling capacity, process inlet and outlet water temperatures, flow rate, condenser-water conditions, annual operating hours and load variations. System reliability can be increased through options such as multiple compressors, independent refrigerant circuits, capacity control and N+1 redundancy.

The advanced control system continuously monitors compressors, pumps, water temperatures, operating pressures and safety equipment. With Modbus or BACnet communication options, it can connect to plant automation and provide a suitable infrastructure for remote monitoring, alarm history and energy-performance tracking.

Carnot engineers the TUNDRA Series not merely as a standalone chiller unit, but as an integrated industrial process-cooling solution operating together with the cooling tower, pump group, hydraulic installation and automation system.

Technology and operation

  • Compressor options

    Scroll and screw options address different load requirements.

  • Water-cooled design

    Condenser heat is transferred to the plant’s cooling-water circuit.

  • Indoor acoustics

    A design without air-condenser fans on the unit.

TUNDRA

Technical specifications

Capacity
30–4,000 kW
Compressor
Scroll / screw
Refrigerant
R407C
Heat rejection
Water-cooled
Placement
Plant room

Capacity and operating temperatures are selected for your process load and site conditions.

Download Catalogue

Frequently asked questions

Answers to common technical questions about selection, application and operation.

Let's engineer solutions tailored to your needs

By analyzing your process and operational data against engineering criteria, we determine capacity, system configuration, and implementation details. Let's turn your technical requirements into the right equipment selection and an actionable system design.